Vascular screening

Vascular screening

Vascular screening

Vascular Screening Device – Vasera 2000 by Fukuda Denshi

Product Code:

Arterial Stiffness measurement made easy with VaSera 2000
The VaSera 2000 Vascular Screening Device provides state-of-the-art monitoring and diagnosis of arterial stiffness which presages potential blood circulation disorders. This is particularly important for disorders in the lower limbs, which is a major risk in older patients in Cyprus and may not be successfully monitored by standard blood pressure monitors.

Clinical quality measurement of blood pressure and arterial hemodynamic, allows Practitioners with a very simplified procedure and accurate reporting, to know the vascular age of their patient’s.
The VaSera 2000 is manufactured by Fukuda Deshi, a leading Japanese medical technology producer. The VaSera 2000 device measures the Cardio-Ankle Vascular Index (CAVI), the Ankle Brachial Index (ABI) and the blood pressure. The newly developed device has better flexibility with an integrated touch screen and adjustable trolley and it can be used on a desk.

label
EXAMINATIONS
Blood Pressure

The Vascular Screening Device takes multiple measurements and the doctor can select the measurement with the best quality. On the screen are displayed the Mercury blood pressure meter, the average values and the pulse amplitude graph. The examination conforms with AHA and ESH guidelines.

Cardio-Ankle Vascular Index (CAVI)

The CAVI is the degree of artery stiffness between the heart and ankle. This index is independent of fluctuation in blood pressure and higher becomes, the stiffer the artery is. Therefore, is a very good indication for Atherosclerosis. Using this index you can determined the vascular age of the artery for better understanding by the patient.

Ankle Brachial Index (ABI)

The ABI is the degree of stenosis, occlusion in the peripheral arteries. The early detection of the peripheral artery disease is important because it is one of the major causes to lead in more serious diseases in cardio and cerebrovascular.

Toe Brachial Index (TBI)

By using the toe cuffs (optional), the doctor can measure the toe blood pressure and obtain the TBI. This index can be used for patients with severe calcification or occlusion in lower limbs, which is hard to detect the blood pressure waveforms.

FEATURES & SPECIFICATIONS
Preview function &  network

Various reports for the doctor and the patient are available. The newly designed device can offer print preview of the reports for easy observation of the whole examination. Along with the integrated LAN or WLAN (optional) network the measurements can be sent in a personal computer for easy management of its patient database.

ECG module

The device is equipped with an optional 12-lead ECG module for a more compact and one stop shop device that fits in the doctor office in Cyprus.

Reports:
A printing color report can be selected

Standard report: Concisely presents CAVI, ABI and interpretation.
Detailed report: Enables confirmation of CAVI, ABI, body weight and BMI in time series as well as evaluation of medication effects.
For tester report: Presents data using graphs and illustrations.

Measuring range:

0-300 mmHg

Pressure accuracy:

± 3 mmHg

Measuring method:

Oscillometric 

PCG frequency:

165-280 Hz within -3db

Main unit:

178 (W) x 181 (D) x 315 (H) mm

Display:

297 (W) x 95.5 (D) x 210 (H) mm